Skip to main navigation Skip to main content
  • E-Submission

JKSPE : Journal of the Korean Society for Precision Engineering

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS
Article

광탄성 응력측정을 위한 투과형 원형편광기 제작 및 시험

백태현, 김명수

Construction and Calibration Test of a Transmission-type Circular Polariscope for Photoelastic Stress Measurement

Tae Hyun Baek, Myung Soo Kim
JKSPE 2004;21(3):38-43.
Published online: March 1, 2004
  • 6 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

This paper describes the construction of a circular polariscope. Generally, a circular polariscope contains four optical elements and a light source. The first element following the light source is called the linear polarizer. It converts the ordinary light into plane-polarized light. The second element is a quarter wave plate which converts the plane-polarized light into circularly polarized light. Following the quarter wave plate, a specimen made of transparent photoelastic material is located in a loading device. The second quarter wave plate is set and the last element is the analyzer. These polarizing elements, two quarter wave plates and two linear polarizing filters, were purchased from the USA. Frames and other structures for holding polarizing filters were machined and assembled to be rotated. Light box, which includes four incandescent lamps and two sodium-vapor lamps, was made. In order to proof the function of the newly built polariscope, Tardy compensation test was applied to a rectangular shaped specimen made of poly-carbonate material (PSMl). The error of the fringe constant, which was measured by the newly built polariscope, was within 4.4 percent compared to the standard value of this material. It is possible to make a good quality of polariscope if accurate polarizing filters will be used.

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Construction and Calibration Test of a Transmission-type Circular Polariscope for Photoelastic Stress Measurement
J. Korean Soc. Precis. Eng.. 2004;21(3):38-43.   Published online March 1, 2004