Skip to main navigation Skip to main content
  • E-Submission

JKSPE : Journal of the Korean Society for Precision Engineering

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS

Page Path

8
results for

"피드백"

Article category

Keywords

Publication year

Authors

Funded articles

"피드백"

Regular

Effect of a Voice-coil-based Seat-integrated Haptic System on Affective Experience during Audiovisual Content
Chang-Gyu Lee
J. Korean Soc. Precis. Eng. 2026;43(11):1233-1239.
Published online November 1, 2026
DOI: https://doi.org/10.7736/JKSPE.026.00073
Emotional engagement is a critical factor in audiovisual entertainment environments such as movies, performances, and immersive exhibitions. This study developed a voice-coil-based seat-integrated vibrotactile system and investigated its effects on users’ affective experiences during audiovisual content consumption. Unlike conventional wearable haptic devices, the proposed system provides vibrotactile feedback through the seat structure without requiring equipment, offering a practical configuration for public audience environments. A total of 127 participants were randomly assigned to either an audiovisualonly condition (AV) or an audiovisual condition with synchronized seat vibrotactile feedback (AVH). Participants viewed 50 emotion-inducing video clips categorized into neutral, fun, sadness, anger, and fear. Subjective responses were collected using self-assessment questionnaires measuring valence, arousal, dominance, liking, and emotion intensity. The data were analyzed using linear mixed-effects models (LMMs) to account for repeated measurements and variability among participants and stimuli. The results showed that the AVH condition was associated with significantly higher arousal and lower dominance scores than the AV condition. In addition, sadness and fear intensities increased significantly under vibrotactile feedback. Significant interaction effects were observed for valence in sadness, liking in fun and sadness, and anger intensity in fear, indicating that seat-integrated vibrotactile feedback can modulate affective experiences depending on audiovisual content.
  • 167 View
  • 4 Download

Special

Trends in Tactile Feedback-based Grasp Intelligence and Applications in Precision Manufacturing
Subin Im, Jaeseon Lee
J. Korean Soc. Precis. Eng. 2026;43(11):1175-1184.
Published online November 1, 2026
DOI: https://doi.org/10.7736/JKSPE.026.00069
Robotic grasping in unstructured environments demands closed-loop feedback that goes beyond conventional fixed open-loop force control. Vision sensors suffer from occlusion at the instant of contact, whereas wrist-mounted force/torque sensors cannot resolve local shear stress distributions or incipient slip at multi-contact interfaces. Tactile sensors bridge this gap by mapping high-dimensional contact physics directly and in real time. This paper surveys grasp intelligence technology within a Perception–State Estimation–Action framework. Specifically, it reviews optical and arraytype tactile sensors; slip detection algorithms, ranging from physics-based local deformation analysis to deep spatiotemporal networks; and active closed-loop force regulation, including diffusion-policy-based reactive control. Applications in precision semiconductor and electronics assembly are then discussed. Finally, outstanding challenges in mechanical durability, ultra-low-latency data processing, intelligent tactile skin, and multi-modal Vision-Language-Action integration are identified as priorities for future research.
  • 251 View
  • 8 Download

Regular

Development of a Gravity Compensation Device for Machining Large Space Optical Mirrors
SangMun Kim, Hagyong Kihm, SangHeon Lee
J. Korean Soc. Precis. Eng. 2026;43(10):1045-1052.
Published online October 1, 2026
DOI: https://doi.org/10.7736/JKSPE.026.00059
Large optical mirrors for space applications require accurate surface evaluation between successive corrective machining steps. Without proper compensation for self-weight, gravitational deformation can affect the measured surface figure and thereby reduce the reliability of the machining process. In this study, an air-cylinder-based gravity compensation device was developed to maintain the target support loads for large optical mirrors. A proportional–integral–derivative (PID) controller with load-cell feedback was implemented, and the initial gains obtained using the Ziegler–Nichols method were retuned on the basis of the measured system response. Single-axis experiments showed that the retuned controller met the specified performance requirements for overshoot, settling time, and steady-state error, even when applied to air cylinders with different spring reaction forces. The validated control method was then applied, via a sequential multi-channel control scheme, to a five-axis gravity compensation system to assess its applicability to multi-point gravity compensation. The experimental results confirmed stable convergence to the target support loads and effective load regulation at steady state, demonstrating that the proposed system is suitable for the multi-point gravity compensation of large optical mirrors.
  • 902 View
  • 11 Download
Articles
Development of a Portable Air Pump-based Microflow Controller Using AI Video Analysis Feedback Control
Woohyun Park, Minseok Kim
J. Korean Soc. Precis. Eng. 2024;41(12):965-972.
Published online December 1, 2024
DOI: https://doi.org/10.7736/JKSPE.024.098
Microfluidics allows for precise manipulation of small volumes of analytical solutions in diverse applications, including disease diagnostics, drug efficacy testing, chemical analysis, and water quality monitoring. Among these diverse applications, one of the most critical aspects is the precise and programmable control of flow within microfluidic control devices. However, microfluidic experiments that employ pressure control via a gas tank may encounter restricted mobility. To address these challenges, we developed an air pump feedback control system utilizing artificial intelligence image analysis and devised a method to enhance portability. In this paper, we utilized a commercially available portable pump to achieve the desired pressure and subsequently cease operation. In addressing the challenge of sustaining prolonged pressure, we implemented a strategy wherein the dimensions of the pressure vessel were modified, accompanied by iterative pump activations, thereby ensuring the sustained maintenance of pressure over time. The evaluation of the flow controller developed in this study involves conducting a comparative flow analysis with established pneumatic flow controllers. Furthermore, we employed artificial intelligence image analysis methods to automate the operation of iterative pumps. In conclusion, we anticipate that the developed portable microfluidic control device will lead to innovative advancements in modern technology and healthcare through its potential applications.
  • 462 View
  • 8 Download
Development of a Controllable Thermo-hygrostat Incubator for Bacterial Cell Culture on a Microfluidic Device
Woohyun Park, Jaehwan Kim, Minseok Kim
J. Korean Soc. Precis. Eng. 2023;40(6):449-456.
Published online June 1, 2023
DOI: https://doi.org/10.7736/JKSPE.023.006
Advances in cell culture technology have improved the understanding of the physiological principles of cells. Recently, the development of microfluidic chips has made it possible to observe single cells in a massively parallelized and accurate manner. However, in order to maximize the availability of the microfluidic cell chip, it is essential to use an incubator that can isolate the cell culture chip from the outside while minimizing contamination and maintaining the temperature and humidity required for cell culture for a long time period. Here, we developed a thermo-hygrostat incubator consisting of an Arduino-based feedback control module for controlling a temperature and humidity complex sensor, a humidifier, and a heater. The temperature and humidity of the incubator could be actively changed according to the needs and application by simple editing control variables of Arduino coding. To demonstrate the efficiency of the device, we conducted an experiment comparing the growth of bacterial cells and obtained optimal conditions necessary for culture. In conclusion, it is expected that the newly developed thermo-hygrostat incubator can be used for a variety of purposes that require active control of temperature and humidity, as well as for long-term cultivation of bacterial cells inside a microfluidic chip.
  • 762 View
  • 4 Download
Study on Performance Improvement at Flexure Piezo Stage Using Feedforward and Snap
Taehwa Hong, Jinho Lee, Hyoyoung Kim, Kihyun Kim
J. Korean Soc. Precis. Eng. 2020;37(8):587-593.
Published online August 1, 2020
DOI: https://doi.org/10.7736/JKSPE.020.017
Recently, instrument stages using flexure guide mechanisms and piezo actuators have been widely used for an ultra-precision positioning system in various industries. Research into ultra-precision position control aiming at nanoscale position errors during stage driving is being actively conducted, as well as various studies on the motion profile adjusting the reference input. In this study, we suggested a motion profile with snap and feedforward for use with a high speed nano scanning system, as compared and analyzed with the position tracking error through feedback control, and also compared to the related feed with the forward control noted as minimized at the position error to 14.19 nm. As a result, a tracking error when applying the fourth profile with snaps to the piezoelectric stage, is obtained with an error reduction effect of about 15%, as compared to when the second profile is applied.
  • 451 View
  • 2 Download
The Development of Smart Insole for Improvement of Human Body Imbalance during Walking
Seung Rok Kang, Jae Wook Nah, Chul Un Hong, Tae Kyu Kwon
J. Korean Soc. Precis. Eng. 2018;35(1):53-59.
Published online January 1, 2018
DOI: https://doi.org/10.7736/KSPE.2018.35.1.53
The purpose of this study was to develop and verify the smart insole based FSR sensor for measurement and improvement of the muscle strength imbalance. We recruited 15 subjects with muscle strength difference over 20% and 15 subjects with muscle strength balance below 10%. We developed the human body load insole and integrated modules using FSR sensor. Subjects walked for 5 minutes at a slope of 0% and a speed of 3 km / h on a treadmill with a smart insole. We measured the real-time muscle activity and foot pressure according to the muscle strength imbalance during gait. FSR data of the developed smart insole showed that the insole had similar accuracy and efficacy as muscle activity and foot pressure. This is the interval in which the muscle imbalance shifts from the stance phase to the load reaction, and the weight support is the largest, and the center of gravity of the human body passes over the whole foot, which is considered to cause the greatest imbalance. This suggests that there is a direct or indirect correlation between muscle strength imbalance of the lower limb and the imbalance of the body weight distribution during gait.

Citations

Citations to this article as recorded by  Crossref logo
  • Design and manufacturing of a smart insole
    Seung Joo Lee, Chae Young Park, In Hwan Lee
    Sensors and Actuators A: Physical.2026; 397: 117225.     CrossRef
  • Functional evaluation of air insoles and methodology for determining the optimal thickness according to weight group
    Seungnam Min, Murali Subramaniyam, Heeran Lee
    International Journal of Industrial Ergonomics.2024; 101: 103582.     CrossRef
  • Development of Plantar Pressure Distribution Measurement Shoe Insole with Built-in Printed Curved Sensor Structure
    Seung Yoon Jung, Chaima Fekiri, Ho-Chan Kim, In Hwan Lee
    International Journal of Precision Engineering and Manufacturing.2022; 23(5): 565.     CrossRef
  • STUDY ON VISION-BASED MULTIDIRECTIONAL POSTURE AND MOTION ANALYSIS SYSTEM DEVELOPMENT
    WOO SUK CHONG, MI YEON SHIN, CHANG HO YU
    Journal of Mechanics in Medicine and Biology.2019; 19(08): 1940059.     CrossRef
  • 618 View
  • 5 Download
  • Crossref
Equipment Maintenance Environment Based on Field-Data of Root Industry by Manufacturing-Field Analysis
Dong-Hong Kim, Jun-Yeob Song
J. Korean Soc. Precis. Eng. 2017;34(1):19-22.
Published online January 1, 2017
DOI: https://doi.org/10.7736/KSPE.2017.34.1.19
This paper describes the efficient equipment maintenance that can offer the exact time for repair and change of component in root industry. A conventional method offered the fixed time for repair and change of component because the method is based on early guarantee specification of the component. However the operating condition of manufacturing field is often under worse condition than early guarantee condition for high productivity. So, most components can’t use until early guarantee time due to the operation of various different condition. Therefore we suggest the useful method for efficient equipment-maintenance by manufacturing-field analysis and feedback database. For this, the classification of root industry and related equipment is performed and then the detail classification of the process and component for equipment maintenance. And the monitoring module is also designed to gather data for feedback process and the environment is basically implemented for aging and reliability test.
  • 365 View
  • 0 Download